Civic HX Coupe L4-1668cc 1.7L SOHC (VTEC-E) MFI (2001)
18. Remove the crankshaft position (CKP) sensor from the oil pump without disconnecting the connector.
19. Apply a force of 98 Nm (10 kgf-cm, 22 ft. lbs.) to the timing belt at the mid point between the camshaft pulley and the water pump pulley and
check that the auto-tensioner move smoothly.
^
If the auto-tensioner does not move smoothly, replace the auto-tensioner.
^
Inspect the auto-tensioner when replacing the timing belt.
20. Move the auto-tensioner to remove tension from the timing belt, then remove the timing belt.
Installation
Special Tools Required
^
Holder handle 07JAB-001020A
^
Holder attachment, 50 mm, offset 07MAB-PY3010A
^
Socket, 19 mm 07JAA-001020A or a commercially-available 19 mm socket
NOTE: If you are removing the auto-tensioner, refer to the auto-tensioner installation procedure.
1. Clean the timing belt pulleys, and the upper and lower covers.