Air Door Actuator / Motor: Service and Repair
Recirculation Control Motor

Recirculation Control Motor Replacement

1. Remove the ECM/PCM.

2. Remove the bolt and the bracket (A). Disconnect the 7P connector (B) and the harness clip (C) from the recirculation control motor (D). Remove

the self-tapping screws and the recirculation control motor from the blower unit.

3. Install the motor in the reverse order of removal. Make sure the pin on the motor is properly engaged with the linkage. After installation, make

sure the motor runs smoothly.