Civic LX Sedan L4-1590cc 1.6L SOHC MFI (1998)
Heater Control Valve Cable: Adjustments
1. From under the hood, open the cable clamp, then disconnect the heater valve cable from the heater valve arm.
2. From under the dash, disconnect the heater valve cable housing from the cable clamp, and disconnect the heater valve cable from the air mix
control arm.
3. Set the temperature control dial on MAX COOL with the ignition switch ON (II).
4. Attach the heater valve cable to the air mix control arm as shown in the illustration. Hold the end of the heater valve cable housing against the
stop, then snap the heater valve cable housing into the cable clamp.
5. From under the hood, turn the heater valve arm to the fully closed position as shown, and hold it. Attach the heater valve cable to the heater valve
arm, and gently pull on the heater valve cable housing to take up any slack, then install the heater valve cable housing into the cable clamp.