Civic LX Sedan L4-1590cc 1.6L SOHC MFI (1998)
Pressure Plate: Specifications
DIMENSIONS
Pressure Plate
Standard (New) .......................................................................................................................................................................... 0.03 mm (0.001 inch)
Service Limit ............................................................................................................................................................................. 0.15 mm (0.006 inch)
Diaphragm Spring Fingers
Standard (New) .............................................................................................................................................................................. 0.6 mm (0.02 inch)
Service Limit ................................................................................................................................................................................. 1.0 mm (0.04 inch)
TIGHTENING SPECIFICATIONS
Attaching Bolt ....................................................................................................................................................................................... 25 Nm (19 ft. lbs.)