honda Workshop Repair Guides

Honda Workshop Service and Repair Manuals

Heater Control Valve > < Expansion Valve|Service and Repair
Page 2
background image

9. Reverse procedure to install, noting the following:

a. Use new O-rings when installing expansion valve and connecting refrigerant lines.
b. Install expansion valve and secure valve sensor against suction line with tape.
c. Reinstall evaporator sensor in its original location.
d. Ensure there is no air leakage in the evaporator housing.

Heater Control Valve > < Expansion Valve|Service and Repair