honda Workshop Repair Guides

Honda Workshop Service and Repair Manuals

Blower Motor|Removal and Installation|Page 6640 > < Diagram Information and Instructions|Page 6637
Page 1
background image

Blower Motor: Service and Repair
Removal and Installation

NOTE:  The blower motor, recirculation control motor and blower resistor can be replaced without removing the blower unit.

1. Move the temperature control to "HOT." 

'96-98: Slide the temperature control lever. 
'99-00: Turn the ignition switch ON (II), then turn the temperature control knob. Turn the ignition switch off.

2. Remove the glove box.

3. Remove the self-tapping screw and the passenger's dashboard lower cover. Remove the bolt, the nut and the knee bolster, then remove the five

bolts and the glove box frame.

Without Air Conditioning

4-a.

Remove the wire harness from the heater duct, then remove the two self-tapping screws and the heater duct.

Blower Motor|Removal and Installation|Page 6640 > < Diagram Information and Instructions|Page 6637