Heated Glass Element Relay: Testing and Inspection

Power Relay Test 

Normally-open type:

1. Check for continuity between the terminals.

-

There should be continuity between the No.1 and No.3 terminals when power and ground are connected to the No.2 and No.4 terminals.

-

There should be no continuity between the No.1 and No.3 terminals when power is disconnected.

Blower Motor/Rear Window Defogger Relay - Type 1

Blower Motor/Rear Window Defogger Relay - Type 2