honda Workshop Repair Guides

Honda Workshop Service and Repair Manuals

Inside Diameter|Page 1405 > < Inside Diameter|Page 1403
Page 1
background image

Valve Guide: Service and Repair

REPLACEMENT 

 

1. As illustrated, use a commercially available air-impact valve guide driver attachment modified to fit the diameter of the valve guides. In most

cases, the same procedure can be done using the special tool and a conventional hammer.

2. Select the proper replacement guides, and chill them in the freezer section of a refrigerator for about an hour.

3. Use a hot plate or oven to evenly heat the cylinder head to 300°F (150°C). Monitor the temperature with a cooking thermometer. Do not get the

head hotter than 300°F (150°C); excessive heat may loosen the valve seats.

CAUTION: To avoid burns, use heavy gloves when handling the heated cylinder head. 

4. Working from the camshaft side, use the driver and an air hammer to drive the guide about 2 mm (0.1 inch) towards the combustion chamber. This

will knock off some of the carbon and make removal easier. Hold the air hammer directly in line with the valve guide to prevent damaging the
driver.

CAUTION: Always wear safety goggles or a face shield when driving valve guides. 

Inside Diameter|Page 1405 > < Inside Diameter|Page 1403