honda Workshop Repair Guides

Honda Workshop Service and Repair Manuals

Fuel Delivery and Air Induction > < Positive Crankcase Ventilation|Locations|Page 2652
Page 1
background image

Positive Crankcase Ventilation: Testing and Inspection

Inspection

1. Check the PCV hoses and connections for leaks and clogging.

2. At idle, make sure there is a clicking sound from the PCV valve when the hose between the PCV valve and intake manifold is lightly pinched with

your fingers or pliers.
If there is no clicking sound, check the PCV valve grommet for cracks or damage. If the grommet is OK, replace the PCV valve and recheck.