Shift Solenoid: Testing and Inspection

1. Disconnect the solenoid valve connector (2P).
2. Measure the resistance between the No. 1 terminal (solenoid valve A) of the connector and body ground, and between the No. 2 terminal (solenoid

valve B) and body ground.
STANDARD: 12 - 25 Ohms

3. Replace the shift solenoid valves A and B if the resistance is out of specification.
4. If the resistance is within the standard, connect the No. 1 terminal of the connector to the battery positive terminal. A clicking sound should be

heard. Connect the No. 2 terminal to the battery positive terminal. A clicking sound should be heard. Replace the shift solenoid valves A and B if
no clicking sound is heard when either terminal is connected to the battery positive terminal.