honda Workshop Repair Guides

Honda Crosstour 2WD V6-35L Workshop Service and Auto Repair Manuals

Electrical - GR8 Battery Diagnostic Station Update Info.|Page 178 > < Electrical - GR8 Battery Diagnostic Station Update Info.|Page 176
Page 3
background image

*

NOTE:

If the wrong software file appears or is not shown, click Change MUP File, and select the correct software version.*

10. Turn on the GR8, and follow the Update Wizard on-screen instructions.

11. When the update is complete, the Update Results screen appears, indicating the update was successful. Click Finish to close the Update Wizard.

12. Turn the GR8 off for 10 seconds. Reinstall the SD card, then turn the GR8 on, and confirm that the software is updated to the software version

listed under SOFTWARE VERSION.

13. If an error message appears anytime during the update, follow the on-screen instructions, and try updating the GR8 again. If the error message still

does not go away, or if you have any problems updating the GR8, call Midtronics.

14. If you have more than one GR8, repeat the update procedure for each unit.

15. Once all GR8s are updated, store the USB-to-mini-USB cable in a safe location for future updates.