Blower Motor: Description and Operation

How The Circuit Works

The blower control circuit regulates the operation of the three-speed blower motor. The speed of the motor is set with the blower switch. The switch
can be set to ''Lo,'' ''Med,'' or ''Hi.''

The position of the blower switch determines the path to ground for the current flowing through the blower motor. With the switch in Lo," two
resistors are included in the circuit. With the switch in "Med," one resistor is included in the circuit. The resistors drop a portion of the circuit voltage,
slowing the motor speed. With the switch set to "Hi," no resistors are included in the circuit. Most of the circuit voltage is dropped across the motor,
causing it to run at high speed.

With the ignition switch in "Run," voltage is applied through fuse 14 to the blower motor. With the blower switch set to "Lo," current flows through
the fuse, the blower motor, both blower resistors, and the "Lo" contacts of the switch to ground. The motor runs at low speed.

When you set the blower switch to "Med," current flows through the fuse, the blower motor, one blower resistor, and the "Med" contacts of the blower
switch to ground. The motor runs at medium speed.

When you set the blower switch to "Hi," current flows through the fuse, the blower motor, and the "Hi" contacts of the blower switch to ground. The
motor runs at high speed.