Air Door Cable: Adjustments
Recirculation Control Rod

1.

Ensure recirculation motor is properly installed, disconnect control rod from recirculation door lever, then turn on ignition and push in REC button
to energize motor.

2.

Hold recirculation door closed and snap control rod into clip on door lever.

3.

Operate REC control several times to ensure door opens and closes fully. Ensure motor remains cool if doors are left in each position for 2
minutes.