CRX Si L4-1590cc 1.6L SOHC (D16A6) MFI (1988)
Condenser Fan Motor Relay: Testing and Inspection
Fig. 32 Typical clutch & fan relay
1.
Check for continuity between terminals 3 and 4, Fig. 32. There should no continuity.
2.
Connect a 12 volt battery across terminals 1 and 2. There should be continuity between 3 and 4.