instructions for test connections and settings. When performing alternator and regulator tests with tester note the following:

a. When checking alternator output, operate engine at 2000 RPM with engine cooling fan off. Turn on headlamps and rear window defogger.

Apply a load to charging system so that voltage drops to no lower than 12 volts. Tester readings should be within 10 amps of the readings
indicated in Fig. 12. If readings are within specification, the charging system is operating properly, refer to ``Charge Warning Lamp Test.'' If
readings are not within specification, proceed to step b.

Fig. 10 Alternator full field access hole location. 1988 units

b. Remove protective cover from alternator end cover. Perform full field test by inserting a suitable tool into full field access hole located on

end cover, Fig. 10. When alternator is in full field, system voltage will rise quickly. Do not allow voltage to exceed 18 volts or damage
to electrical system may result. Note tester amperage readings with alternator in full field. If readings are still not within
specification, replace alternator. If readings are now within specification, refer to step 7.