Evaporative Shut Valve: Service and Repair

EVAP Canister Vent Shut Valve Replacement

1. Remove the EVAP canister.

2. Pry the lock tabs outward (A), then remove the EVAP canister vent shut valve (B).

NOTE:  Be careful not to damage the lock tabs.

3. Install the valve in the reverse order of removal with a new O-ring (C).

NOTE:  Do not coat the O-ring with engine oil etc.