Element 4WD L4-2.4L (2004)
Connecting Rod: Testing and Inspection
Connecting Rod Bolt Inspection
Inspection
1. Measure the diameter of each connecting rod bolt at point A and point B.
2. Calculate the difference in diameter between point A and point B.
Point A-Point B = Difference in Diameter
Difference in Diameter:
Specification: 0 - 0.1 mm (0 - 0.004 inch)