Connecting Rod: Testing and Inspection
Connecting Rod Bolt Inspection

Inspection 

1. Measure the diameter of each connecting rod bolt at point A and point B.
2. Calculate the difference in diameter between point A and point B.

Point A-Point B = Difference in Diameter

Difference in Diameter: 

Specification: 0 - 0.1 mm (0 - 0.004 inch) 

3. If the difference in diameter is out of tolerance, replace the connecting rod bolt.