honda Workshop Repair Guides

Honda Workshop Service and Repair Manuals

Diagram Information and Instructions|Page 9714 > < Diagram Information and Instructions|Page 9712
Page 7
background image

While You're Working

1. Make sure connectors are clean, and have no loose terminals or receptacles.
2. Make sure multiple terminal connectors are packed with dielectric (silicone) grease. Part Number: 08798-9001.
3. When connecting a connector, push it until it clicks into place.

CAUTION:

^

Do not pull on the wires when disconnecting a connector. Pull only on the connector housings.

^

Most circuits include solid-state devices. Test the voltages in these circuits only with a 10-megaohm or higher impedance digital multimeter.
Never use a test light or analog meter on circuits that contain solid-state devices. Damage to the devices may result.

Short to Ground With  Self-Powered Test Light or DVOM

1.  Remove the blown fuse and disconnect the battery and load.
2.  Connect one lead of a self-powered test light or Digital Volt/Ohmmeter (DVOM) (switched to the lowest "OHMS" range) to the fuse terminal on

the load side.

3.  Connect the other lead to a known good ground.
4.  Beginning near the fuse box, wiggle the harness. Continue this at convenient points about six inches apart while watching the test light or DVOM.
5.  If the self-powered test light goes on or the DVOM displays a low reading or no reading (ZERO), there is a short to ground in the wiring near that

point.

Short to Ground With A Short Circuit Locator (Short Finder)

Diagram Information and Instructions|Page 9714 > < Diagram Information and Instructions|Page 9712