Odyssey V6-3.5L (2003)
Power Sliding Door Module: Testing and Inspection
Sliding Door Lock System
Sliding Door Lock System
Control Unit Input Test
1. Remove the left sliding door panel.
2. Disconnect the 8P connector (A) from the sliding door control unit (B).
3. Inspect the connector and socket terminals to be sure they are all making good contact.
-
If the terminals are bent, loose or corroded, repair them as necessary, and recheck the system.
-
If the terminals look OK, go to step 4.
4. Close the sliding door.
5. Make these input test at the connector.
-
If any test indicates a problem, find and correct the cause, then recheck the system.