honda Workshop Repair Guides

Honda Workshop Service and Repair Manuals

Dual Air Conditioning (Rear A/C)|Page 8401 > < Dual Air Conditioning (Rear A/C)
Page 2
background image

9. Connect the No.1 terminal of the rear blower motor main relay 6P connector to the No.3 terminal of the rear blower motor high relay 4P connector

with a jumper wire.
Does the blower motor run? 

YES-Go to step 10.

NO-Repair open in the BLK wire between the low, middle, high blower motor relays or poor ground at G582.

10. Turn the ignition switch ON (II).
11. Measure the voltage between the No.6 terminal of the rear blower motor main relay 6P connector and body ground.

Is there battery voltage?

YES-Go to step 12.

NO-Repair open in the wire between the No.3 fuse in the driver's under-dash fuse/relay box and the rear blower motor main relay.

12. Turn the ignition switch OFF.
13. Disconnect the rear A/C control dial 10P connector.

14. Check for continuity between the No.8 terminal of the rear A/C control dial 10P connector and body ground.

Is there continuity'?

YES-Test the rear A/C control dial and the rear A/C passenger control panel.

NO-Check for an open in the wire between the rear A/C control dial and body ground. If the wire is OK, check for poor ground at G401.

15. Disconnect the jumper wire.
16. Disconnect the rear blower motor 2P connector.

Dual Air Conditioning (Rear A/C)|Page 8401 > < Dual Air Conditioning (Rear A/C)