Daytime Running Lamp Control Unit: Testing and Inspection

Daytime Running Lights Control Unit Input Test - Canada

1. Remove the glove box.

2. Disconnect the 14P connector (A) from the daytime running lights control unit (B).
3. Inspect the all connector and socket terminals to be sure they are all making good contact.

-

If the terminals are bent, loose, or corroded, repair them as necessary, and recheck the system.

-

If the terminals look OK, go to step 4.