Odyssey EX V6-3.5L (1999)
11. Measure the brush (A) length. If it is not within the service limit, replace the brush holder assembly.
Brush Length
Standard (New): 15.8-16.2 mm (0.62-0.64 in.)
Service Limit: 11.0 mm (0.43 in.)
Starter Brush Holder Test
12. Check that there is no continuity between the (+) brush holder (A) and (+) brush holder (B). If there is continuity, replace the brush holder
assembly.
13. Insert the brush IA into the brush holder, and bring the brush into Contact with the commutator, then attach a spring scale (B) to the spring (C).
Measure the spring tension at the moment the spring lifts off the brush.
Spring Tension: 15.7-17.7 N (1.6-1.8 kgf, 3.53-3.97 lbf)