honda Workshop Repair Guides

Honda Workshop Service and Repair Manuals

Air Mix Control Motor Test|Page 6946 > < Air Mix Control Motor Test|Page 6944
Page 12
background image

9. Turn the ignition switch ON (II), and check the same terminals for voltage.

Is there any voltage?

YES - Repair any short to power in the wire(s) between the heater control panel and the recirculation control motor This short may also damage
the heater control panel Repair the short to power before replacing the heater control panel.

NO - Go to step 10.

10. Turn the ignition switch off.

11. Check for continuity between the following terminals of the heater control panel 22P connector and the recirculation control motor 7P connector. 

22P:   7P:
No.1   No.7
No.11  No.5

Is there continuity?

YES - Check for loose wires or poor connections at the heater control panel 22P connector and at recirculation control motor 7P connector If the
connections are good, substitute a known good heater control panel, and recheck If the symptom/indication goes away, replace the original heater
control panel.

NO - Repair any open in the wire(s) between the heater control panel and the recirculation control motor.

12. Remove the recirculation control motor.
13. Check the recirculation control linkage and doors for smooth movement.

Do the recirculation control linkage and doors move smoothly?

YES - Replace the recirculation control motor.

NO - Repair the recirculation control linkage or doors.

Recirculation Control Motor Test

Recirculation Control Motor Test

1. Disconnect the 7P connector from the recirculation control motor.

NOTE:  Incorrectly applying power and ground to the recirculation control motor will damage it. Follow the instructions carefully.