18. Reconnect the door multiplex control unit, and perform the following input test.

-

If any test indicates a problem, find and correct the cause, then recheck the system.

-

If all the input tests prove OK, go to step 19.

19. If all the input tests prove OK, one of the control units must be faulty. Substitute a known-good control unit for the one that is most likely at fault,

then check the system. If the system works properly, the original control unit is faulty; replace it. If there is still a malfunction, substitute a
known-good control unit for the next most likely unit to be at fault, and recheck. If the system works properly, the original unit is faulty; replace it.