Condenser Fan: Description and Operation
95 1/2 Model

With the engine running, battery voltage is applied through fuse EB-15 to the A/C switch button, battery voltage is applied to the A/C triple pressure
switch senses pressure above 1078.7±117.7kPa (218.3±14.2 psi), its contacts close, applying voltage to the coil of the condenser fan relay. The fan relay
contacts when close applying voltage to the condenser fan through fuse EB-17.