EGR Valve: Service and Repair

Removal / Replacement

1. Remove Air Cleaner Duct Assembly.
2. Disconnect Vacuum Hoses from EGR Valve.
3. Disconnect EGR Pipe.
4. Remove the two Retaining bolts from Valve.
5. Remove EGR Valve and Gasket.

Installation

To install, follow the removal steps in the reverse order. 

5. Install EGR Valve & new Gasket.
4. Connect Retaining Bolts to Valve.
3. Install EGR Pipe.
2. Reconnect Vacuum Hoses to EGR Valve.
1. Install Air Cleaner Dust Assembly.