This is the same power supply used by the PGM Tester. 

*The PC Interface Kit and the 110 VAC/12 VDC Power Supply can be ordered through the Honda Tool and Equipment Program at 888-424-6857.

^

Dealer Communications System (DCS) CD: May 1999 or later

^

HONDANET DCS Workstation (not the master terminal)

^

PGM Tester with SN902 or later software:

The Tester can be used to retrieve PCM broadcast codes if you aren't using the Smart Cable to retrieve codes.*

*USING A PROGRAMMED SMART CABLE 

NOTES:
*

If the PCM broadcast code stored in the Smart Cable is different than the code needed by the PCM, go to REPROGRAMMING A SMART
CABLE.*

^

If the red light (# 3) on the Smart Cable comes on or flashes at any time during the procedure, the update was not completed. Go to SMART CABLE
DIAGNOSIS.

1.

Turn the ignition switch ON (II).

2.

Connect the Smart Cable's large blue connector to the vehicle's DLC (data link connector). Connect the other end of the Smart Cable to the DLC
port on the Smart Cable box. The green light (# 1) on the Smart Cable flashes, then glows steadily.

*NOTES

If the yellow (# 2) and green lights flash and then glow steadily, the PCM broadcast code already matches the code in the Smart Cable. Go to steps
5.*

3.

Momentarily push and release the START button on the Smart Cable to begin the PCM update. While updating the PCM, the yellow light on the
Smart Cable flashes, and the green light glows steadily.

*NOTICE 

To avoid permanent PCM damage, do not disconnect the Smart Cable or turn the ignition switch OFF while the yellow light is flashing.*

4.

After 1 to 3 minutes, note that both the yellow and green lights glow steadily to indicate that the update is complete.

5.

Disconnect the Smart Cable from the DLC.

6.

If the vehicle still has the problem you tried to correct with the update, refer to the appropriate service manual or ETM for troubleshooting
information.

*REPROGRAMMING A SMART CABLE

1.

If not already done, load the May 1999 or later DCS CD onto your DCS workstation. Loading instructions were included in the CD's mailing. It
you have questions when loading the CD, contact the HONDANET 2000 Support Center at 800-245-4343.

2.

Connect the small end of the PC interface kit to the PC port on the Smart Cable box. (Some kits have a yellow label near the small end to help you

PCM- Smart Cable Programming Procedures|Page 1912 > < PCM- Smart Cable Programming Procedures