honda Workshop Repair Guides

Honda Workshop Service and Repair Manuals

Blower Motor - Will Not Run In One Or More Settings|Page 6011 > < Blower Motor - Will Not Run In One Or More Settings|Page 6005
Page 1
background image

Blower Motor Resistor: All Technical Service Bulletins
Blower Motor - Will Not Run In One Or More Settings

01-007

October 16, 2001

Applies To: 
1998-01 Passport - ALL

Blower Does Not Run in One or More Settings 
(Supersedes 01-007, dated July 3, 2001)

SYMPTOM

The blower does not run in one or more fan control lever positions.

PROBABLE CAUSE

A high current draw on the blower resistor causes it overheat and to become electrically "open." This high current draw is usually caused by high friction
in the blower motor bearings and/or debris in the blower assembly housing, which jams or slows the blower motor and damages its commutator.

CORRECTIVE ACTION

Replace the blower resistor and the blower motor assembly. Clean out all debris from inside the blower assembly housing.

PARTS INFORMATION

Blower Resistor (1998-99 models):

P/N 8-97078-452-1, H/C 4906202

Blower Resistor (2000-01 models):

P/N 8-97260-283-0, H/C 6633390 

Blower Motor Assembly (1998-99 models):

P/N 8-97231-642-0, H/C 6447544

Blower Motor Assembly (2000-01 models):

P/N 8-97229-613-1, H/C 6262083

WARRANTY CLAIM INFORMATION

In warranty: 
The normal warranty applies.

Operation Number:

612109

Flat Rate Time:

0.4 hour

Failed Part:

P/N 8-97046-497-0 
H/C 4402186

Defect Code:

032

Contention Code:

B01

Template ID:

01-007A (1998-99 models)
01-007B (2000-01 models)

Skill Level:

Repair Technician

Out of warranty: 
Any repair performed after warranty expiration may be eligible for goodwill consideration by the District Service Manager or your Zone Office. You
must request consideration, and get a decision, before starting work.

REPAIR PROCEDURE

Blower Motor - Will Not Run In One Or More Settings|Page 6011 > < Blower Motor - Will Not Run In One Or More Settings|Page 6005