Refrigerant Pressure Sensor / Switch: Testing and Inspection
Triple Pressure Switch

1. Disconnect the connector and check for continuity between pressure switch side connector terminals (1) and (2).
2. Reconnect the connector to activate the A/C switch and check to see if there is continuity between the chassis side connector terminals (3) and (4)

and the fan operates.

Dual Pressure Switch|Page 6314 > < Dual Pressure Switch