Ambient Temperature Sensor / Switch HVAC: Testing and Inspection

Connect battery power to the No. 3 terminal, ground the No. 2 terminal, and connect a test light between the No. 1 and No. 3 terminals.

NOTE:  Use a 12 V3 W-18 W test light.

Dip the A/C thermostat into a cup filled with ice water, and check the test light.

The light should go off at 36 - 39° F (2 - 4° C) or less, and should come on at 39 - 41° F (4 - 5° C) or more.

If the light doesn't come on and go off as specified, replace the A/C thermostat.