honda Workshop Repair Guides

Honda Workshop Service and Repair Manuals

Float Test|Page 2944 > < Float Test
Page 1
background image

Refueling Control Valve: Testing and Inspection
Valve Test

1. Make sure the fuel tank is less than half full.
2. Remove the fuel fill cap.

3. Remove the fuel hose joint protector. Disconnect the ORVR signal tube.

4. Disconnect the vacuum hose from the EVAP control canister, and then plug the ports with plugs.
5. Disconnect the vacuum hose from the EVAP control canister vent shut valve, and connect a vacuum pump to the vacuum hose.
6. Pump the vacuum pump 80 times.

-

If the vacuum holds, go to step 7.

-

If the vacuum does not hold, go to step 9.

7. Connect a second vacuum pump to the ORVR signal tube.
8. Apply vacuum (1 pump) to the ORVR signal tube, then check the vacuum on the pump in step 6.

-

If the vacuum holds, replace the ORVR vent shut valve.

-

If the vacuum is released, the ORVR vent shut valve is OK.

Float Test|Page 2944 > < Float Test