Prelude L4-2157cc 2.2L DOHC (VTEC) MFI (2001)
Shift Fork: Testing and Inspection
Clearance Inspection
CLEARANCE INSPECTION
NOTE: The synchro sleeve and synchro hub should be replaced as a set.
1. Measure the clearance between each shift fork and its matching synchro sleeve.
-
Standard: 0.35 - 0.65 mm (0.014 - 0.026 inch).
-
Service Limit: 1.00 mm (0.039 inch).
2. If the clearance exceeds the service limit, measure the thickness of the shift fork fingers.
-
If the thickness of the shift fork finger is less than the standard, replace the shift fork with a new one.
-
If the thickness of the shift fork finger is within the standard, replace the synchro sleeve with a new one.
3. Measure the clearance between the shift fork and the shift arm.
-
Standard: 0.2 - 0.5 mm (0.008-0.019 inch).
-
Service Limit: 0.6 mm (0.024 inch).