Air Door Actuator / Motor: Component Tests and General Diagnostics

Mode Control Motor

1. Disconnect the 10P connector from the mode control motor.

2. Connect battery power to the No. 2 terminal, and ground the No. 1 terminal; the mode control motor should run smoothly, and stop at VENT. If it

doesn't, reverse the connections; the mode control motor should run smoothly, and stop at DEF.

CAUTION:  When the mode control motor stops running, disconnect battery power immediately.

3. When the mode control motor running in step 2, check for continuity between the No. 4, 5, 6, 7, 8 and 9 terminals and the No. 10 terminal

individually. There should be continuity for a moment.

CAUTION:  Use a digital multimeter with an output of 1 mA or less at the 20 K Ohm range.

4. If the mode control motor does not run in step 2, remove it, then check the mode control linkage and doors for smooth movement. If they move

smoothly, replace the mode control motor.

Recirculation Control Motor

1. Disconnect the 5P connector from the recirculation control motor.

2. Connect battery power to the No. 5 terminal, and ground the No. 1 and No. 2 terminals; the recirculation control motor should run smoothly.

CAUTION:  Never connect the battery in the opposite direction.

3. Disconnect the No. 1 or No. 2 terminals from ground; the recirculation control motor should stop at FRESH or RECIRCULATE.

NOTE:  Don't cycle the recirculation control motor for a long time.

4. If the recirculation control motor does not run in step 2, remove it, then check the recirculation control linkage and doors for smooth movement. If

they move smoothly, replace the recirculation control motor.