S2000 L4-1997cc 2.0L DOHC (VTEC) MFI (2001)
15. Connect battery power to PGM-FI main relay 7P connector terminal No.2 and connect ground to the PGM-FI main relay 7P connector terminal
No.1. Then check for continuity between PGM-FI main relay 7P connector terminals No.5 and No.4.
NOTE: Use the terminal numbers shown. Ignore the terminal numbers molded into the relay.
Is there continuity?
YES - Go to step 16
NO - Replace the PGM-FI main relay and recheck the circuit.
16. Connect battery power to PGM-FI main relay 7P connector terminal No.5, and connect ground to PGM-FI main relay 7P connector terminal No.3.
Then check for continuity between PGM-FI main relay 7P connector terminals No.7 and No.6.
Is there continuity?
YES - Go to step 17.
NO - Replace the PGM-FI main relay and recheck the circuit.
17. Connect battery power to PGM-FI main relay 7P connector terminal No.6, and connect ground to PGM-FI main relay 7P connector terminal No.1.
Then check for continuity between PGM-FI main relay 7P connector terminals No.5 and No.4.
Is there continuity?
YES - The PGM-FI main relay is OK.
NO - Replace the PGM-FI main relay and recheck the circuit.