S2000 L4-1997cc 2.0L DOHC (VTEC) MFI (2001)
Check for continuity between the terminals.
-
There should be continuity between the No.1 and No.2 terminals when power and ground are connected to the No.3 and No.4 terminals.
-
There should be no continuity between the No.1 and No.2 terminals when power is disconnected.
Five-terminal type B:
Check for continuity between the terminals.
-
There should be continuity between the No.1 and No.2 terminals when power and ground are connected to the No.3 and No.5 terminals.
-
There should be continuity between the No.1 and No.4 terminals when power is disconnected.
-
Intermittent wiper relay ('00-01 models)
-
Rear window defogger relay ('02-03 models)