honda Workshop Repair Guides

Honda Workshop Service and Repair Manuals

Refueling Control Valve, Evaporative System|Locations|Page 2614 > < Refueling Control Valve, Evaporative System|Locations
Page 1
background image

Refueling Control Valve: Testing and Inspection

Fuel Tank Vapor Control Valve Test

Special Tools Required

Vacuum pump/gauge, 0 - 30 in.Hg A973X-041-XXXXX

Float Test

1. Make sure the fuel tank is less than half full.
2. Remove the fuel fill cap to relieve the fuel tank pressure, then reinstall the cap.

3. Remove the fuel pipe cover. Disconnect the fuel tank vapor recirculation tube (A), and connect a vacuum pump to the hose.
4. Plug the fuel tank vapor recirculation pipe (B).
5. Apply vacuum to the fuel tank vapor recirculation hose (A).

-

If the vacuum holds, replace the fuel tank vapor control valve.

-

If the vacuum does not hold, the float is OK. Go to step 1 of the valve test.

Valve Test

1. Make sure the fuel tank is less than half full.
2. Remove the fuel fill cap,

3. Remove the fuel pipe cover. Disconnect the fuel tank vapor signal hose (A).

Refueling Control Valve, Evaporative System|Locations|Page 2614 > < Refueling Control Valve, Evaporative System|Locations