Accent L4-1.6L (2003)
Harness Inspection Procedures
ACTUATOR INSPECTION
RESISTANCE MEASUREMENT BETWEEN TERMINALS
1. Disconnect the connector at the idle speed control actuator.
2. Measure the resistance between terminals.
Standard value
Terminal 1 and 2 : 16.6 - 18.6 Ohm
Terminal 2 and 3 : 14.5-16.5 Ohm [at 20 °C (68 °F)]
3. Connect the connector to the idle speed control actuator.