Accent L4-1.6L (2003)
Using Voltmeter
Harness Inspection Procedure
SENSOR INSPECTION
1. Disconnect the throttle position sensor connector.
2. Measure the resistance between terminals 2 (sensor ground) and terminal 3 (sensor power).
Standard value :0.7 - 3.0 kOhm
3. Connect an analog ohmmeter between terminals 2 (sensor ground) and terminal 1 (sensor output).
4. Operate the throttle valve slowly from the idle position to the full open position, and check that the resistance changes smoothly in proportion with
the throttle valve opening angle.