hyundai Workshop Repair Guides

Hyundai Workshop Service and Repair Manuals

Relays and Modules - Transmission and Drivetrain > < Component Locations|Page 4592
Page 1
background image

Shift Solenoid: Testing and Inspection

A/T SHIFT LOCK SOLENOID

1. Remove the solenoid connector.
2. Using an ohmmeter, measure the resistance between terminals.

Standard resistance : 12 - 16 Ohm

3. Attach the positive (+) lead from the battery to terminal #9. and the negative (-) lead to terminal #8.
4. Check that an operation noise can be heard from the solenoid.

Relays and Modules - Transmission and Drivetrain > < Component Locations|Page 4592