Accent GL Sedan L4-1495cc 1.5L SOHC MFI (1997)
Valve: Testing and Inspection
1. Check each valve for wear, damage and distortion of head and stem at B in illustration. Repair or correct, if necessary.
Valve stem oil clearance standard value:
Intake: 0.030-0.060 mm (0.0012-0.0024 inch).
Exhaust: 0.035-0.065 mm (0.0014-0.0026 inch).
Limit:
Intake: 0.100 mm (0.0040 inch).
Exhaust: 0.150 mm (0.0060 inch).
2. If stem end, A in illustration, is pitted or worn, resurface as necessary.
-
This correction must be limited to a minimum.
-
Also resurface the valve face.
3. Replace the valve if the margin has decreased to less than the service limit.
Standard value:
Intake: 1.10 mm (0.0430 inch).
Exhaust: 1.40 mm ( 0.0550 inch).
Limit:
Intake: 0.80 mm (0.0310 inch).
Exhaust: 1.10 mm (0.0430 inch).