Accent GL Sedan L4-1495cc 1.5L SOHC MFI (1997)
Ignition Coil: Testing and Inspection
CHECKING IGNITION COILS
1. Measurement of the primary coil resistance. Measure the resistance between connector terminals 3 and 1 (the coils at the No.1 and No.4 cylinder
sides) of the ignition coil, and between terminals 3 and 2 (the coils at the No.2 and No.3 cylinder sides).
Standard value : 0.5 ± 0.05 K Ohms
2. Measurement of the secondary coil resistance. Measure the resistance between the high-voltage terminal for the No.1 and No.4 cylinders, and
between the high-voltage terminals for the No.2 and No.3 cylinders.
Standard value : 12.1 ± 1.8 K Ohms
CAUTION: Be sure, when measuring the resistance of the secondary coil, to disconnect the connector of the ignition coil.
CIRCUIT DIAGRAM (SOHC/DOHC)