CHECKING IGNITION COILS
1. Measurement of the primary coil resistance. Measure the resistance between connector terminals 1 and 2.
Standard value : 0.5 ± 0.05 K Ohms
2. Measurement of the secondary coil resistance. Measure the resistance between the high-voltage terminal.
Standard value : 12.1 ± 1.8 K Ohms
CAUTION: Be sure, when measuring the resistance of the secondary coil, to disconnect the connector of the ignition coil.
CIRCUIT DIAGRAM (SOHC/DOHC)