CAUTION:  Do not use a fuse with a higher rating than the specified fuse that protects the circuit being tested. Do not use this tool in any situation to
substitute an input or output at the solid-state control module, such as ECM, TCM, etc.

Short Finder

SHORT FINDER

A short finder is available to locate a short to ground. The short finder creates a pulsing magnetic field in the shorted circuit and shows you the location
of the short through body trim or sheet metal.

Testing For Voltage

TESTING FOR VOLTAGE

This test measures voltage in a circuit. When testing for voltage at a connector, you do not have to separate the two halves of the connector Instead,
probe the connector from the back (backprobe). Always check both sides of the connector because dirt and corrosion between its contact surfaces can
cause electrical problems.

1. Connect one lead of a test lamp or voltmeter to a ground. If you are using a voltmeter, be sure it is the voltmeter's negative test lead you have

connected to ground.

2. Connect the other lead of the test lamp or voltmeter to a selected test point (connector or terminal).
3. If the test lamp glows, there is voltage present. If you are using a voltmeter, note the voltage reading. Too close a loss of more than 1 volt from

specification indicates a problem.

Testing For Continuity