Accent L L4-1495cc 1.5L SOHC MFI (2001)
Evaporator Temperature Sensor / Switch: Testing and Inspection
THERMOSTATIC SWITCH (THERMISTOR)
1. Remove the glove box assembly.
2. Turn the blower and A/C switches ON.
3. Start the engine.
4. With the thermostatic switch connector in coupled state, install a voltmeter between terminal 2 and 3 (-) and check for a change in voltage
according to the temperature of the evaporator surface.
* Thermostatic switch operating characteristics
NOTE: This check should be carried out by back-probing the thermostatic switch when it is connected.