Elantra L4-1595cc 1.6L DOHC (1993)
Ignition Coil: Testing and Inspection
Measurement of the primary coil resistance
1. Measure the resistance between connector terminals 3 and 1 (the coils at the No. 1 and No. 4 cylinder sides) of the ignition coil, and between
terminals 3 and 2 (the coils at the No. 2 and No. 3 cylinder sides).
Standard value: 0.77 - 0.95 ohms
Measurement of the secondary coil resistance
1. Measure the resistance between the high-voltage terminal for the No. 1 and No. 4 cylinders, and between the high-voltage terminals for the No. 2
and No. 3 cylinders.
Standard value: 10.3 - 13.9 K ohms
CAUTION: Be sure, when measuring the resistance of the secondary coil, to disconnect the connector of the ignition coil.