Elantra GLS Sedan L4-2.0L (1999)
Shift Solenoid: Testing and Inspection
1. Remove the solenoid connector.
2. Using an ohmmeter, measure the resistance between terminals.
Standard resistance: 12 - 16 Ohms
3. Attach the positive (+) lead from the battery to terminal 1 and the negative (-) lead to terminal 2.
4. Check that an operation noise can be heard from the solenoid.