hyundai Workshop Repair Guides

Hyundai Workshop Service and Repair Manuals

Diagram Information and Instructions|Page 21 > < Diagram Information and Instructions|Page 19
Page 1
background image

Alarm Module: Testing and Inspection

Check that the following components operates normally as timing chart.

Intermittent Wiper

1. Time specification

T1 : 

0.15 sec. MAX.

T2 : 

0.7 sec. (Time of wiper motor 1 rotation)

T3 : 

1.5 sec. ± 0.7 sec. (VR=0 k Ohms

         

10.5 sec. ± 1 sec. (VR=50 k Ohms)

Wiper Motor Related to Washer S/W

1. Time specification

T1 : 

0.5 sec.

T2 : 

2.5 - 3.8 sec.

Rear Defogger Timer

1. Time specification

T1 : 

0.1 sec.

T2 : 

15 ± 3min.

Seat Belt Warning

1. Time specification

T1 : 6 sec. ± 1 sec.
T2 : 6 sec. ± 1 sec. MAX.
T3, T4 : 

0.3 sec. ± 0.1 sec

Door Warning