Elantra GLS Sedan L4-2.0L (1999)
Alternator: Testing and Inspection
ROTOR
1. Check the rotor coil for continuity. Check to make sure that there is continuity between the slip rings. If resistance is extremely low, it means that
there is a short. If there is no continuity or if there is a short circuit, replace the rotor assembly.
Resistance value: Approx. 2.7 Ohms
2. Check the rotor coil for ground. Check to make sure that there is no continuity between the slip ring and the core. If there is continuity, replace
rotor assembly.
STATOR
1. Make a continuity check on the stator coil. Check to make sure that there is continuity between the coil leads. If there is no continuity, replace
stator assembly.
2. Check the coil for grounding. Check to make sure that there is no continuity between the coil and the core. If there is continuity, replace the stator
assembly.
RECTIFIERS