SERVICE PROCEDURE:

A)

Main Connector Repair:

1.

Disconnect the pulse generator main connector from the engine harness.

2.

Using small needle nose pliers, gently twist the male pins in the pulse generator main connector approximately ten (10) degrees clockwise to
ensure electrical contact.

3.

Clean both ends of the pulse generator connector with aerosol electrical contact cleaner.

4.

Reconnect the main connector.

B)

Test Procedure:

1.

Disconnect the pulse generator main connector from the engine harness.

2.

Use an ohmmeter to check the resistance between the male terminals 1-2 and 3-4 as shown. If the resistance is not within the specification of
215-275 ohms, replace the pulse generator.

3.

If the resistance is within specification, reconnect the pulse generator main connector and use an ohmmeter or HDS sweep test to check the
continuity of the engine harness between the TCM and the pulse generator. The resistance should be 215-275 ohms.

4.

If the resistance is not 215-275 ohms,  carefully check the harness near the engine mounts for damage to the wiring that may cause open or short

A/T - Driveability Concerns/DTC's Set/MIL ON|Page 182 > < A/T - Driveability Concerns/DTC's Set/MIL ON