hyundai Workshop Repair Guides

Hyundai Workshop Service and Repair Manuals

Body Control Module|Locations|Page 7266 > < Body Control Module|Locations|Page 7264
Page 2
background image

T1 : 0.3 ± 0.1s, T2 : more than 0.6s,
T3 : 2.5 - 3.8s ± 0.1s, T4 : INT TIME-0.7s,
T5 : 0.2 - 0.6s, T6 : 0.7 ± 0.1s.

2. MIST INTERLOCKING WIPER

(1) In IGN2 SW ON, if the MIST SW is ON for 60ms or more, within 100ms, and then, wiper output shall be ON for 700ms within 100ms.

T1 : Min 60 ms, T2 : Max 100 ms,
T3 : 700 ± 100 ms.

(2) If MIST SW input is continued, WIPER output shall be maintain the ON state, and then if MIST SW is OFF, the Wiper output shall be ON for

700ms since OFF time.

T1 : Min 60 ms, T2 : Max 100 ms,
T3 : 700 ± 100 ms, T4 : 700 ms

(3) Mist SW input shall be disregarded by INT WIPER, WASHER interlocking WIPER during operating WIPER.

3. INT WIPER

According to the vehicle speed, control intermittent time of the Intermittent Wiper.
A. IGN2 SW ON state.
B. WIPER SW INT state
C. INPUT the vehicle speed and the VOLUME value for setting the intermittent time
(1) Output of Intermittent time ratio

Calculate the INT time rate by inputting the INT Time set Volume value (input voltage)
"The INT Time Rate is to indicate the position where the Volume is located from the Slow (100%) to the Fast (0%) of the Knob. Therefore the
Volume shall be linearly calibrated about the input voltage"

(2) Output of Standard Intermittent Time

"Calculate the intermittent time of the intermittent time ratio 100%and 0% at the vehicle speed (V) computed in (1) term by linear correction "

Body Control Module|Locations|Page 7266 > < Body Control Module|Locations|Page 7264